Draft Details
- Surge protective devices — Type 1 — Permanentl...
- DRAFT STANDARD
- Legal Notice for Draft Standards
- Preface
- + 1 Scope
- 1.1
- 1.2
- 1.3
- 1.4
- 1.5
- 2 Reference publications
- + 3 Definitions and abbreviations
- 3.1 Definitions
- 3.2 Abbreviations
- + 4 Construction
- + 4.1 General
- 4.1.1
- 4.1.2
- 4.1.3
- 4.1.4
- + 4.2 Enclosures
- 4.2.1
- 4.2.2
- 4.2.3
- 4.2.4
- 4.2.5
- 4.2.6
- + 4.3 Overcurrent protection — Internal
- 4.3.1
- 4.3.2
- + 4.4 Supplementary protectors
- 4.4.1
- 4.4.2
- 4.4.3
- 4.4.4
- + 4.5 Spacings
- 4.5.1
- 4.5.2
- 4.5.3
- 4.5.4
- 4.5.5
- 4.5.6
- 4.5.7
- 4.5.8
- 4.5.9
- 4.5.10
- 4.6 Printed circuit boards
- + 4.7 Wiring
- 4.7.1
- 4.7.2
- 4.7.3
- 4.7.4
- 4.7.5
- 4.7.6
- 4.7.7
- 4.7.8
- 4.7.9
- 4.7.10
- + 4.8 Bonding
- 4.8.1
- 4.8.2
- 4.8.3
- 4.8.4
- + 5 Documentation, ratings, and markings
- 5.1
- 5.2
- 5.3
- 5.4
- 5.5
- 5.6
- 5.7
- 5.8
- 5.9
- + 6 Tests
- 6.1 General test requirements
- + 6.2 Combination wave test
- 6.2.1
- 6.2.2
- 6.2.3
- 6.2.4
- + 6.3 Nominal discharge current (In) test
- 6.3.1
- 6.3.2
- 6.3.3
- 6.3.4
- 6.3.5
- 6.3.6
- 6.3.7
- 6.3.8
- 6.3.9
- 6.3.10
- 6.3.11
- 6.4 Operating duty cycle test
- + 6.5 Temperature test (two-port devices or one-p...
- 6.5.1
- 6.5.2
- 6.5.3
- 6.5.4
- 6.5.5
- 6.5.6
- + 6.6 Dielectric withstand test
- 6.6.1
- 6.6.2
- 6.6.3
- 6.6.4
- 6.6.5
- 6.6.6
- 6.6.7
- 6.6.8
- 6.6.9
- + 6.7 Mechanical tests
- + 6.7.1 Impact on polymeric enclosures
- 6.7.1.1
- 6.7.1.2
- 6.7.1.3
- + 6.7.2 Impact on observation/display openings
- 6.7.2.1
- 6.7.2.2
- 6.7.2.3
- 6.7.2.4
- 6.7.2.5
- + 6.7.3 Deflection for metal enclosures and doors...
- 6.7.3.1
- 6.7.3.2
- 6.7.3.3
- + 6.7.4 Pigtail connection pull test
- 6.7.4.1
- 6.7.4.2
- 6.7.4.3
- + 6.8 Short circuit withstand test — For two-port...
- 6.8.1
- 6.8.2
- 6.8.3
- 6.8.4
- + 6.9 Overload behavior test — For two-port devic...
- 6.9.1
- 6.9.2
- 6.9.3
- + 6.10 Overvoltage testing
- + 6.10.1 General
- 6.10.1.1
- 6.10.1.2
- 6.10.1.3
- 6.10.1.4
- 6.10.1.5
- + 6.10.2 Abnormal overvoltage — Short circuit cur...
- 6.10.2.1
- 6.10.2.2
- 6.10.2.3
- 6.10.2.4
- 6.10.2.5
- 6.10.2.6
- 6.10.2.7
- + 6.10.3 Abnormal overvoltage — Intermediate curr...
- 6.10.3.1
- 6.10.3.2
- 6.10.3.3
- 6.10.3.4
- 6.10.3.5
- 6.10.3.6
- 6.10.3.7
- 6.10.3.8
- 6.10.3.9
- + 6.10.4 Abnormal overvoltage — Limited current b...
- 6.10.4.1
- 6.10.4.2
- 6.10.4.3
- 6.10.4.4
- 6.10.4.5
- 6.10.4.6
- 6.10.4.7
- + 6.11 Accessibility test for openings in enclosu...
- 6.11.1
- 6.11.2
- 6.11.3
- 6.11.4
- 6.12 Terminal voltage decay test
- + 6.13 Capacitor endurance test
- 6.13.1
- 6.13.2
- 6.13.3
- 6.13.4
- 6.13.5
- + 6.14 Bonding impedance test
- 6.14.1
- 6.14.2
- 6.14.3
- 6.14.4
- 6.14.5
- 6.14.6
- + 6.15 Insulating material tests
- 6.15.1
- 6.15.2
- 6.15.3
- + 6.16 Dielectric voltage-withstand test in lieu ...
- 6.16.1
- 6.16.2
- + 6.17 Printed circuit board coating test
- 6.17.1
- 6.17.2
- 6.17.3
- 6.17.4
- 6.17.5
- 6.17.6
- 6.17.7
- 6.18 Leakage current test
- Table 1
- Table 2
- Table 3
- Table 4
- Table 5
- Table 6
- Table 7
- Table 8
- Table 9
- Table 10
- Table 11
- Table 12
- Table 13
- Table 14
- Table 15
- Figure 1
- Figure 2
- Figure 3
- Figure 4
- Figure 5
- + Annex A (informative)
- A.0 Introduction
- A.1 Scope
- A.2 Reference publications
- + A.3 Definitions, abbreviations, and symbols
- A.3.1 Definitions and abbreviations
- A.3.2 Symbols
- + A.4 Tests
- + A.4.1 General test requirements
- A.4.1.1
- A.4.1.2
- A.4.1.3
- A.4.1.4
- A.4.1.5
- A.4.1.6
- A.4.1.7
- A.4.1.8
- A.4.1.9 Pass/fail criteria
- + A.4.2 Impulse discharge current tests
- A.4.2.1
- A.4.2.2
- A.4.2.3
- A.4.2.4
- A.4.2.5
- A.4.2.6
- + A.4.3 Impulse discharge current test procedures...
- A.4.3.1
- A.4.3.2
- A.4.3.3
- A.4.3.4
- Table A.1
- Figure A.1
- Figure A.2
- Figure A.3
1.1
This Standard applies to surge protective devices (SPDs) intended for:
a) permanently connected applications designed for limiting surge voltages and discharging surge currents;
b) use on 50/60 Hz circuits over 42 V and up to 750 V ac;
c) installation between the secondary of the service transformer and the line side of the service equipment overcurrent protective device. These devices may also be installed on the load side of the main overcurrent protective device;
d) installation where external overcurrent protection may not be present; and
e) indoor or outdoor use in accordance with the Canadian Electrical Code, Part I.
1.2
Type 1 SPDs intended for use in lightning protection systems are within the scope of this Standard.
1.3
Equipment designed solely for other power disturbances such as notches, sags and noise is not within the scope of this document.
1.4
SPDs discussed in this standard contain at least one voltage limiting or voltage switching component for diverting surge currents or dissipating surge energy, or both. Examples of such components are metal oxide varistors, silicon avalanche diodes, spark gaps and gas discharge tubes. Ferroresonators, motor-generators, uninterruptible power supplies, and filters containing only inductive or capacitive components are not considered SPDs in this standard.
1.5
In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.
Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.
Notes to tables and figures are considered part of the table or figure and may be written as requirements.
Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.
You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.