Draft Details
- Direct plug-in nightlights (Amendment)
- DRAFT AMENDMENT
- Legal Notice for Draft Amendments
- Preface
- + 1 Scope
- 1.1
- 1.2
- + 2 Reference Publications
- 2.1
- 2.2 Products
- CSA Group
- + 3 Components
- 3.1
- 3.2
- 3.3
- 3.4
- 3.5
- + 4 Units of Measurement
- 4.1
- 4.2
- 4.3
- + 5 Application of Requirements
- 5.1
- 5.2
- 5.3
- + 6 Definitions
- + 6.1
- 6.2.1
- + 6.3
- 6.3.1
- 6.4
- 6.5
- 6.6
- 6.7
- 6.8
- 6.9
- 6.10
- 6.11
- 6.12
- 6.13
- 6.14
- 6.15
- 6.16
- 6.17
- 6.18
- 6.19
- 6.20
- + 7 Construction
- + 7.1 Enclosures – General
- 7.1.1
- 7.1.2
- 7.1.3
- 7.1.4
- 7.1.5
- 7.1.6
- 7.1.7
- 7.1.8
- 7.1.9
- 7.1.10
- 7.1.11
- 7.1.12
- + 7.2 Polymeric materials for enclosure and elect...
- 7.2.1
- 7.2.2
- 7.2.3
- 7.2.4
- 7.2.5
- + 7.3 Enclosure assembly methods
- + 7.3.1 Mechanical fastenings
- 7.3.1.1
- 7.3.1.2
- + 7.3.2 Adhesives
- 7.3.2.1
- 7.3.2.2
- + 7.4 Corrosion protection
- 7.4.1
- + 7.5 Current-carrying parts
- 7.5.1
- 7.5.2
- 7.5.3
- + 7.6 Plug blades
- 7.6.1
- 7.6.2
- 7.6.3
- + 7.7 Plug face dimensions
- 7.7.1
- 7.7.2
- 7.7.3
- 7.7.4
- + 7.8 Polarization and identification
- 7.8.1
- 7.8.2
- + 7.9 Switching mechanisms
- 7.9.1
- 7.9.2
- 7.9.3
- + 7.10 Lampholder
- 7.10.1
- 7.10.2
- 7.10.3
- 7.10.4
- 7.10.5
- + 7.11 Wiring and terminal connections
- 7.11.1
- 7.11.2
- 7.11.3
- 7.11.4
- + 7.12 Internal wiring
- 7.12.1
- 7.12.2
- 7.12.3
- + 7.13 Spacing of conductive parts
- 7.13.1
- 7.13.2
- 7.13.3
- 7.13.4
- 7.13.5
- 7.13.6
- + 7.14 Grounding and bonding
- 7.14.1
- 7.14.2
- 7.14.3
- + 7.15 Maximum tipping moment
- 7.15.1
- 7.15.2
- + 7.16 Electroluminescent panels
- 7.16.1
- 7.16.2
- 7.16.3
- + 7.17 Incandescent lamps
- 7.17.1
- + 7.18 LED light sources
- 7.18.1
- 7.18.2
- 7.18.3
- 7.18.4
- 7.18.5
- + 7.19 Receptacle
- 7.19.1
- 7.19.2
- 7.19.3
- 7.19.4
- + 7.20 Ballasts
- 7.20.1
- 7.20.2
- 7.20.3
- 7.20.4
- 7.20.5
- + 7.21 Vessels containing a liquid
- 7.21.1
- + 7.22 Class 2 outputs
- 7.22.1
- + 7.23 Secondary batteries
- 7.23.1
- 7.23.2
- 7.23.3
- 7.23.4
- 7.23.5
- 7.23.6
- 7.23.7
- + 8 General Tests
- + 8.1 General
- 8.1.1
- 8.1.2
- 8.1.3
- + 8.2 Accessibility of live parts
- 8.2.1
- 8.2.2
- + 8.3 Dielectric voltage-withstand
- 8.3.1
- 8.3.2
- 8.3.3
- 8.3.4
- + 8.4 Plug blades accessibility
- 8.4.1
- + 8.5 Secondary battery tests
- 8.5.1
- 8.5.2
- 8.5.3
- 8.5.4
- 8.5.5
- 8.5.6
- + 9 Normal Operation Tests
- + 9.1 Temperature
- 9.1.1
- 9.1.2
- 9.1.3
- 9.1.4
- 9.1.5
- + 9.2 Lampholder and lamp base accessibility
- 9.2.1
- 9.2.2
- 9.2.3
- 9.2.4
- + 10 Component Tests
- + 10.1 Switch mechanism
- + 10.1.1 General
- 10.1.1.1
- 10.1.1.2
- 10.1.1.3
- 10.1.1.4
- 10.1.1.5
- + 10.1.2 Overload
- 10.1.2.1
- 10.1.2.2
- + 10.1.3 Endurance
- 10.1.3.1
- 10.1.3.2
- + 10.1.4 Actuating members
- 10.1.4.1
- + 10.2 Plug blade secureness test
- + 10.2.1 General
- 10.2.1.1
- + 10.2.2 Pull test
- 10.2.2.1
- 10.2.2.2
- + 10.2.3 Loading test
- 10.2.3.1
- + 10.3 Folded blade compression test
- 10.3.1
- + 10.4 Mold stress-relief distortion test
- 10.4.1
- 10.4.2
- + 10.5 Lamp cavity separation test
- 10.5.1
- 10.5.2
- + 10.6 Pull test
- 10.6.1
- 10.6.2
- + 10.7 Enclosure impact test
- 10.7.1
- 10.7.2
- 10.7.3
- 10.7.4
- + 10.8 Battery charge and discharge measurement
- 10.8.1
- 10.8.2
- + 11 Abnormal Tests
- + 11.1 Blanketing test
- 11.1.1
- 11.1.2
- 11.1.3
- 11.1.4
- 11.1.5
- 11.1.6
- 11.1.7
- + 11.2 Overlamping test
- 11.2.1
- + 11.3 Limited short-circuit test
- 11.3.1
- 11.3.2
- 11.3.3
- 11.3.4
- + 11.4 Overvoltage test
- 11.4.1
- 11.4.2
- 11.4.3
- + 11.5 Component breakdown test
- 11.5.1
- 11.5.2
- 11.5.3
- + 11.6 Voltage surge test
- 11.6.1
- 11.6.2
- 11.6.3
- 11.6.4
- 11.6.5
- 11.6.6
- + 11.7 Humidity conditioning test
- 11.7.1
- 11.7.2
- 11.7.3
- + 11.8 Leakage-current test
- 11.8.1
- 11.8.2
- 11.8.3
- 11.8.4
- 11.8.5
- 11.8.6
- 11.8.7
- 11.8.8
- + 11.9 Grounding continuity test
- 11.9.1
- 11.9.2
- 11.9.3
- 11.9.4
- + 11.10 Crush test
- 11.10.1
- 11.10.2
- + 11.11 Torque test
- 11.11.1
- 11.11.2
- 11.11.3
- + 11.12 Rotational endurance test
- 11.12.1
- 11.12.2
- 11.12.3
- + 11.13 Envelope torque test
- 11.13.1
- + 12 Factory Production Tests
- + 12.1 Dielectric voltage-withstand test
- 12.1.1
- 12.1.2
- 12.1.3
- 12.1.4
- 12.1.5
- 12.1.6
- 12.1.7
- + 12.2 Additional factory production tests in Can...
- 12.2.1
- + 13 Marking
- 13.1
- 13.2
- 13.3
- 13.4
- 13.5
- 13.6
- 13.7
- 13.8
- 13.9
- + Tables
- Table 1
- Table 2
- Table 3
- Table 4
- Table 5
- Table 6
- + Figures
- Figure 1
- Figure 2
- Figure 3
- Figure 4
- Figure 5
- Figure 6
- Figure 7
- Figure 8
- Figure 9
- Figure 10
- Figure 11
- Figure 12
- Figure 12A
- Figure 13
- Figure 14
- Figure 15
- + Annex A (Normative) Standards for components
- A.1
- + Annex B (CAN) (Normative) Grounding and bondin...
- + B.1 General
- B.1.1
- + B.2 Impedance
- B.2.1
- + B.3 Impedance Test
- B.3.1
- B.3.2
- B.3.3
- + ANNEX C (CAN) (Normative) Printed circuit-boar...
- + C.1 Application
- C.1.1
- + C.2 Special Terminology
- C.2.1
- C.2.2
- C.2.3
- C.2.4
- C.2.5
- C.3.1
- + Table C.1
- C.3.2
- C.3.3
- + C.4 Printed Circuit-Board Coatings Tests
- + C.4.1 Dielectric strength
- C.4.1.1
- C.4.1.2
- C.4.1.3
- C.4.1.4
- + C.4.2 Adhesion
- C.4.2.1
- C.4.2.2
- C.4.2.3
- C.4.2.4
- C.4.2.5
- C.4.2.6
- C.4.2.7
- + C.4.3 Abrasion resistance test apparatus
- C.4.3.1
- Figure C.1
- + Table C.2
- + C.4.5 Fault conditions test
- C.4.5.1
- + C.5 Bond Strength of Printed-Wiring Boards
- + C.5.1 General
- C.5.1.1
- C.5.1.2
- + C.5.2 Test procedure
- C.5.2.1
- C.5.2.2
- C.5.2.3
- C.5.2.4
- + Annex D (CAN) (Normative) Factory Tests for Ca...
- + D.1 Grounding continuity
- D.1.1
- D.1.2
- D.1.3
- + D.2 Separation
- D.2.1
- D.2.2
- D.2.3
- + D.3 Candelabra lamp devices
- D.3.1
- D.3.2
- + D.4 Test records
- D.4.1
- Annex E (CAN) (Informative) French translation...
1.1
This Standard applies to direct plug-in nightlights not exceeding 10 W input, for indoor use only, in non-hazardous locations and intended to be used in accordance with the Canadian Electrical Code, Part I, CSA C22.1, and the National Electrical Code, ANSI/NFPA 70. Light source types include incandescent candelabra base lamps, non-replaceable lamps, [fluorescent, neon, or light-emitting diode (LED) type] or electroluminescent panels.
1.2
These requirements cover direct plug in nightlights for insertion into a parallel slot receptacle rated 125 volts maximum.
1.3
These requirements do not cover:
(a) cord-connected luminaires;
(b) nightlights with more than one receptacle;
(c) direct plug-in devices with other primary functions, such as room deodorizers, insect repellers, or rechargeable flashlights; or
(d) direct plug-in devices utilizing plasma light.
You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.