Draft Details

Designation:C22.2 NO. 61010-2-202
Source:CSA
Review start date:Apr 22, 2021
Review end date:Jun 21, 2021
Categories:Electrical
Contact email:mary.morgan(at)csagroup.org
Associated materials (click link to download). You will need to be logged in to download any files:

Adobe Acrobat For PDF files, Adobe Acrobat Reader can be downloaded from the Adobe website.

Draft Scope/Description:

1.1.1 Equipment included in scope 

Replacement: 
Replace the text by the following paragraphs: 

This part of IEC 61010 specifies the safety requirements for electric ACTUATORs and SOLENOIDs, as applied to valves, intended to be installed in an industrial process or discrete control environment. 

This part of IEC 61010 specifies: 

- particular safety requirements for general purpose electrically operated valve ACTUATORs and SOLENOIDs,
- related verification tests. 

The general purpose electrically operated valve ACTUATORs and SOLENOIDs, covered by this part of IEC 61010 are limited to: 
 
- those rated 600 V alternative current/ 840 V direct current or less, 

Service personnel interface to equipment included in the scope of this document. 

1.1.2 Equipment excluded from scope 

Addition at the end of the list: 

This Standard excludes 

- electric ACTUATORs and SOLENOIDs for use in explosive atmospheres, as covered by the IEC 60079 series of standards;
- mechanical parts/aspects of valves;
- ACTUATORs and SOLENOIDs performing a safety function as covered by the IEC 61508 series of standards;
- POSITIONERs. 

NOTE: A positioner is defined as a physical unit delivering an additional, often mechanical, feedback to a mechanical final controlling element that improves its velocity and precision in IEC 60050-351:2013, 351-56-17. 

You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.