Draft Scope/Description:

This document sets the general and dimensional interchangeability requirements for plugs, socket-outlets, connectors and appliance inlets with arcuate contacts of standardized configurations (hereinafter referred to as accessories), with a rated operating voltage not exceeding 600 V AC at a frequency of 50 Hz and 60 Hz and with rated currents of 20 A and 30 A, primarily intended for commercial use indoors, in conditions where the presence of water is negligible.

This document applies to accessories for use when the ambient temperature is normally within the range of –25 °C to +40 °C. These accessories are intended to be connected to cables of copper or copper alloy only.

Interchangeability requirements are defined for IP20 accessories.

NOTE The conditions of use indoors are based on the limitations given by IEC 60364-5-51:2005, Table 51A, AD1.

Socket-outlets or appliance inlets incorporated in or fixed to electrical equipment are within the scope of this document.

1DV [D1] Modify the “Scope” first paragraph by replacing with the Clauses 1DV.1, 1DV.2:

1DV.1 This Standard covers the general and dimensional interchangeability requirements for plugs, connectors, receptacles, adaptors, appliance inlets, current taps and similar devices with arcuate contacts of standardized configurations (hereinafter referred to as accessories), with a rated operating voltage not exceeding 600 V AC at a frequency of 50 Hz and 60 Hz and with rated currents of 20 A and 30 A, and intended for use in accordance with CE Code, Part I.

1DV.2 This Standard does not apply to the following products:

a) Straight-blade attachment plugs, receptacles, cord connectors, and inlets, covered by CSA C22.2 No 42;
b) Cord sets and power supply cords covered by CSA C22.2 No 21;
c) Cord reels and multi-outlet assemblies covered by CSA C22.2 No 308;
d) Devices having male or female screw shells, covered by CSA C22.2 No 43;
e) Receptacles, attachment plugs, connectors and adaptors of the special use types covered by CSA C22.2 No. 182.1, CSA C22.2 No. 182.2, CSA C22.2 No. 182.3 and CSA C22.2 No. 182.4;
g) Devices intended for hazardous locations covered by CSA C22.2 No 25 & CSA C22.2 No 30;
i) Devices incorporating ground-fault circuit interruption circuitry, covered by CSA C22.2 No 144.1;

You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.