Draft Details

Designation:C22.2 NO. 164
Source:CSA
Contact:ana.andronescu@csagroup.org
Review start date:Sep 13, 2017
Review end date:Nov 12, 2017
Categories:Electrical
Contact email:mary.morgan(at)csagroup.org
Draft Scope/Description:

1 Scope

1.1

This Standard applies to permanently-connected electric sauna (dry bath) heating equipment rated 300 V and less, designed to be installed and used in ordinary locations in accordance with the Rules of the Canadian Electrical Code, Part I.

1.2

This standard applies to the following electric sauna heating equipment:

(a)  sauna heater unit intended for fixed installation in a special room that is built or assembled in the field to conform to the manufacturer's size specifications; and

(b)  combination of a sauna heater or heater units and a prefabricated, factory-built room or cabinet in which the assembled combination may be specified for field installation, or that may be supplied with a power supply cord and intended to be fastened in place or located in a dedicated space.  The room may be arranged so that it can be taken apart for shipment.

1.3

Clauses 4 to 7 apply to the heater unit described in Clause 1.2(a) and Clause 8 applies to the combination of a heater unit and the room as described in Clause 1.2(b).

1.4

The requirements in Clauses 4 to 7 do not apply to steam bath equipment.

1.5

Throughout these requirements, the term "heater" is used broadly to refer to any sauna heater or heater unit, including its associated control assembly.

1.6

The values given in SI units are the units of record for the purposes of this Standard. The values given in parentheses are for information and comparison only.

1.7

In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (nonmandatory) to define their application.

You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.