Draft Details

Designation:B182.4
Source:CSA
Review start date:Mar 6, 2019
Review end date:May 6, 2019
Contact email:sarah.chung(at)csagroup.org
Draft Scope/Description:

1 Scope

1.1

This Standard specifies requirements for profile polyvinylchloride (PVC) sewer pipe and fittings of pipe stiffness 70 and 320 (PS70 and PS320), based on controlled inside diameter.

Notes:

1) Pipe and fittings manufactured in accordance with this Standard should be installed in accordance with CSA B182.11.

2) Industrial waste disposal lines should be installed only with the approval of the authority having jurisdiction because chemicals not commonly found in drains and sewers, and temperatures greater than 60 °C, can be encountered.

3) When PS70 pipe is used, the appropriate authority having jurisdiction should be consulted.

1.2

In this Standard, “shall” is used to express a requirement, i.e., a provision that the user is obliged to satisfy in order to comply with the Standard; “should” is used to express a recommendation or that which is advised but not required; and “may” is used to express an option or that which is permissible within the limits of the Standard.

Notes accompanying clauses do not include requirements or alternative requirements; the purpose of a note accompanying a clause is to separate from the text explanatory or informative material.

Notes to tables and figures are considered part of the table or figure and may be written as requirements.

Annexes are designated normative (mandatory) or informative (non-mandatory) to define their application.

You may comment on any section of this document by clicking the “Submit Comment” link at the bottom of the relevant section.